Version: v2.7.0
Date: 2025-03-20
MCR54
NEW:
• Added FLAT compander for audio measurement.
• Added compatibility with new Bluetooth module.
• Optimized latency.
• Improved detection on MRK16.
BUG FIX:
• BT Sync issue.
Version: BootL v1.2
Date: 2025-03-20
MCR54
Added firmware update with MRK16 via Ethernet
Version: v2.6.0
Date: 2023-09-08
MCR54
Version: v2.5.0
Date: 2024-06-25
MCR54
NEW:
- Added PTT management through MRK16.
BUG FIX:
- Audio routing with SONY socket.
- Compander/modulation setting during Bluetooth SYNC.
Version: v2.4.0
Date: 2023-09-12 11:51:49
MCR54
- Added Bluetooth SYNC function (for compatibility with MTP61)
- Fixed failure to save “FN parameter”
Version: v2.3.0
Date: 2023-04-20 13:30:22
MCR54
Use Wisycom Manager 3.4 or later to update.
Changes:
- added JNS compander.
- added PTT management (compatibility wth Manager 3.4 or higher).
- new user interface (added PTT seletion and Audio Route menu)
Bug FIXES:
- Audio routing on PTT while using SEN compander.
- Fixed audio bar data initialization.
- Fixed base analog level control on MRK16.
- Fixed Rx3/Rx4 output selection.
- No digital audio output with BPA54 and Ikegami slot-in
Version: BootL v1.1
Date: 2023-03-29
MCR54
Added compatibility with additional microcontroller revisions
NOTE: compatible with Sound Device SL2
Version: v1.23.0
Date: 2022-07-11 08:44:10
MCR54
Added:
- BT App compatibility
- Compander NONE-d75 narrowband compatibility
- Antenna tip in INFO page
Fixed:
- Frequency scan forbidden on SYNC group
- Improved antennas selection on bottom for MRK16 base
- Scan functionality improvements
- TX battery icon optimized
- Graphic deviation audio bar optimized
- While into MRK16, changed highlighting receiver indication
- Minor bugs fix
Version: v1.22.0
Date: 2022-02-16 11:53:37
MCR54
New:
- Added compatibility with MRK16
- Added SYNC process with MTP60
- Improved compatibility with MTP60 (ENS compander)
- Improved display layout
- Added support of Narroband modulation for NONE_75us compander
- Activation of ENS compander if not available
- Set quick access to Headphone page pressing EXIT+SEL buttons
- Changed default receiver name from “RECEIVERn” to “RXn”
- Changed compander after a Factory Preset (from ENR to ENS)
Bug FIX
- Fixed bump noise issue during RX selection headphone
- Fixed group selection issue in SCAN Channels function
- Fixed set frequency issue after a SCAN Frequency function
Version: V1.10
Date: 2021-08-06 13:59:19
MCR54
Added:
– Single Rx view page.
– Removed 3 seconds SAVE confirmation button.
– Removed “Saved” popup when a parameter is changed.
– Logo updated.
– Modulation mismatch pop up updated.
– New “Set to All” function to automatically assign the best 4 scan results to the currently active receivers.
– New RF bars from 0 to 80 dBuV in 10 dBuV steps.
Bug FIX:
– Fixed missing compander/ChMod/cal tone control when the receiver is not active.
– Fixed mute/unmute control on AUX out.
Version: v1.9
Date: 2021-07-09 10:20:28
MCR54
Bug Fix:
- Minor bug fix.
- Tone Squelch is enabled only if the compander supports it.
- When receiver is out of the front end, input passband filter (BW=32MHz), audio and RF bars are disabled
Version: V1.8
Date: 2021-02-24 16:25:32
MCR54
– Removed: automatic display power-on when audio is activated
– Removed: display OFF suspension until audio is active
– Automatic closure of popup signalling a mismatch on compander or modulation bandwidth when the issue clears up
– Fixed: enhanced battery data decoding to avoid compander mismatches false warnings caused by battery bytes
– Fixed: display misalignment due to wrong command readout
– Fixed: GR/CH saving when channel is changed and new frequency value is store
– Fixed: default compander selection, ENR if enabled, otherwise JNR.
– Fixed: text shown when selected modulation bandwidth is not compatibile with current compander
Version: v1.7
Date: 2020-11-12 11:00:11
MCR54
Added:
– IRDA bridge feature for remote control of Wisycom Transmitters by Wisycom Manager equal or higher v3.1.0
– Channel SCAN command for compatibility with Sound Device SL-2
– 8/16-bit telemetry decoding
– Improved multiple frequency set up after a Channel SCAN
– Improved shutdown sequence
– OFF timeout display unit changed from minutes to seconds
– Squelch mode OFF removed
– USER mode Noise squelch range reduced to 8-25 dB
– In the main overview display RF Squelch level replaced with Squelch mode
Bug Fix:
– Calibration tone issue
– Graphic artifact after the Freq. SCAN
– Generic minor graphic issues
– Serial Communication stall when incoming data have baud rate different from 115200
Version: v1.5
Date: 2020-09-07 07:22:43
MCR54
Fixed:
- minor bug on frequency settings
- seldom random conditions could trigger a device software shut down
Version: v1.3
Date: 2020-07-23 10:33:50
MCR54
- Fixed USB startup freezing
- Fixed Calibration Tone Status
- Fixed EXT_ON Pin Logic
- Fixed Audio Bar Attack-Release
- Added Socket SN under Info Menu
- Menu Text Updates
- Power On Time Decrease
- Updated Sockets Compatibility
- Updated Minor DSP Parameters
- Introduced Selectable Level on SX Sockets
Version: v1.2
Date: 2020-07-02 10:09:16
MCR54
- changed Squelch mode name (from “Aggressive” to “Long Range”)
- changed default value of delay of Squelch ON (from 500ms to 0)
- changed Noise Squelch hysteresis (from 8dB to 4dB)
- added RTS/CTS Bluetooth control
- added Wisycom protocol compatibility on Bluetooth UART
- added UART communication with the rear panel
- fixed led issue when receivers are OFF
- fixed TX reference warning during battery TX alarm
- fixed initialisation of the AES output at 48KHz